Medium Voltage Withwrawable Switchgear

Medium voltage withwrawable switchgear Admin Edit

Min. Order: 1 Piece/Pieces
Trade Term: FOB,CFR,CIF
Payment Terms: L/C, T/T
Place of Origin: Zhejiang, China (Mainland)
Brand Name: SASUN

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

SASUN

Model Number:

KYN28-12 switchgear

12KV swichgear:

metal-clad enclosed switchgear

rated current:

630~2000A

rated current of dynamic stability (4S):

16/20/25/31.5/40/50KA

Protection degree.:

IP2X&IP4X





Packaging & Delivery

Packaging Details:Packaging Detail: wooden box
Delivery Detail:35days after getting prepayment

   KYN28A-12(Z) Metalclad AC Indoor Enclosed Switchgear,

 

Withdrawable type,  3KV,6KV,11KV , 12KV 

 

 1. General Description

 

1.1 Application: In the power system of 3.6  to 12kV, for control, protection and monitoring.VCBs produced

 

By CNHK or VCBs produced by other manufactures could be installed in the switchgear panel.

 

1.2 Standards : IEC 62271-200

 

1.3 Parameters: Rated voltage: 3.6V

 

1.4 Rated current: 630-5000A

 

1.5 Rated short-circuit breaking current: 16kA

 

 

 

2.Features:

 

2.1.Compact design

 

2.2.Easy operation and installation

 

2.3.Reliable interlock

 

2.4.Less Maintenance

 

 

 

3.Technical Data

 

No.

Item

Unit

Data

3.1

Rated voltage

kV

3.6,7.2,12

3.2

Rated current of circuit breaker

A

630,1250,1600,2000,2500,3150,4000,5000

Rated current of switchgear

A

630,1250,1600,2000,2500,3150,4000,5000

3.3

Rated frequency

Hz

50

3.4

 

Rated short-circuit breaking current

kA

16,20,25,31.5,40,50

Rated short-time withstand current

kA

16,20,25,31.5,40,50

Rated short circuit continuous time

s

4

3.5

Rated peak withstand current

kA

40,50,63,80,100,125

Rated short-circuit closing current(peak)

kA

40,50,63,80,100,125

3.6

Rated insulation level: 1min power frequency withstand voltage

kV

24,32,42 between poles, pole to earth

kV

24,32,48 between open contacts

3.7

Rated insulation level: Lighting impulse withstand voltage(peak)

kV

40,60,75 between poles, pole to earth

kV

46,70,85 between open contacts

3.8

Rated power frequency withstand voltage

kV

95/1min

3.9

Protection level

Switchgear shell


IP3X

Compartments(door opened)


IP2X when the CPT and CB doors are open.

 

Note: 1.The short circuit capacity of the current transformer should be separately considered.

 

       2. See technical parameters of ZN63A(VS1)-12 in related product of our company.


Related Products

PRODUCT DETAIL HV INDOOR SF6 LOAD BREAKER SWITCHGEAR

HV INDOOR SF6 LOAD BREAKER SWITCHGEAR

FLN36-12D
PRODUCT DETAIL RAIN MAIN UNIT --Fully sealed SF6 filled metalswitch panel

RAIN MAIN UNIT --Fully sealed SF6 filled metalswitch panel

XGN15-12
PRODUCT DETAIL Solid Insulated Ring Main Unit

Solid Insulated Ring Main Unit

DH-SRM12
PRODUCT DETAIL outdoor SF6 vaccum circuit breaker

outdoor SF6 vaccum circuit breaker

ZW32-12
PRODUCT DETAIL 11kv 630a outdoor load break switch

11kv 630a outdoor load break switch

FZW28(VSP5)-12
PRODUCT DETAIL Medium Voltage SF6 Ring Main Unit

Medium Voltage SF6 Ring Main Unit

Pannel Unit
PRODUCT DETAIL HV Indoor AC SF6 Load Breaker Switchgear

HV Indoor AC SF6 Load Breaker Switchgear

FLN48-12D

Category: Ring Main Unit