HV INDOOR SF6 LOAD BREAKER SWITCHGEAR

HV INDOOR SF6 LOAD BREAKER SWITCHGEAR Admin Edit

Min. Order: 2 Piece/Pieces
Payment Terms: Paypal, L/C, D/P, T/T, WU
Place of Origin: Zhejiang, China (Mainland)
Means of Transport: Ocean, Air, Land
Brand Name: SASUN

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

SASUN

Model Number:

SF6

Type:

High Voltage

Poles Number:

3

Classification:

China Circuit Breaker

Standards:

IEC 62271-105

Rated voltage:

12kV

Rated current:

630A

Rated frequence:

AC50HZ

Ambient air temperature:

-25°C~ +40°C

Altitude:

≤1000m

Packaging & Delivery

Packaging Details:China Circuit Breaker : Standard export cases
Delivery Detail:15 days

FLN36-12D SF6 11kv High Voltage China Circuit Breaker      

 


   SF6 Gas Circuit Breaker

1.Application: It adopts SF6 gas as an arc extinguishing and Insulation medium. It includes three contactors for switching on and switching off. It is also for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network .

2.Standards: IEC 62271-105

3.Parameters:    Rated voltage: 12kV.  
                               Rated current:  630A .
                               Rated frequence:AC50HZ.

 

   


   SF6 Gas Circuit Breaker

 

1.Easy operation and installation

 

2.Connection combination is simple and convenient

 

3.Insulation and sealed structure,

 

4.Reliable interlock, compact design

 

 

 

 

 


   SF6 Gas Circuit Breaker

1 Ambient air temperature: -25°C~ +40°C

2 Altitude: ≤1000m

3 No operation in such places as subject to dust, smog, corrosive/flammable gas, vapor and salt pollution.

4 Relative humidity: Daily average ≤ 95%

                              Monthly average ≤ 90%

5 Water vapor pressure: Daily average ≤2.2kPa

                                     Monthly average ≤1.8kPa

6 The external shocking and earthquake from the switchgear and control equipment could be neglected.

7 The amplitude of electromagnetic interference in the second system ≤1.6kV

Note: Customized products for other special working conditions are available on your requirements.

 

 

 

 

 


 

1. Load switch

 

 

2 Load switch-Combination of electrical

 

 

 

 

 

 

 


 

Manual Spring operation mechanism(Fig.1)   

(Operation voltage: AC220V, DC220V)

 

 

 

 

Electric Spring operation mechanism(Fig.2)

 

 

 

 

 

 


 

1 Data for Load Break Switch

Item

Unit

Data

FLN36-12D

FLRN36-12D

Rated voltage

kV

12

Rated frequency

Hz

50

Rated current

A

630

125

Load switch rated short-time withstanding current/Rated short-circuit duration time

kA /s

20/3

___

Earthing switch rated short-time withstanding current/Rated short-circuit duration time

kA/s

20/3

___

Rated peak withstanding current and rated short-circuit making current

kA

50

125(expected)

Rated insulation level

1min power frequency with stand voltage(Phase to earth, between poles, open contacts)

kV

42/48

42/48

Rated lightning impulse withstand voltage(Phase to earth, between poles, open contacts)

kV

75/85

75/85

Rated breaking current

Power load breaking current

A

630

_

Close loop breaking current

A

630

_

5% Power load breaking current

A

31.5

_

Breaking cable charge current

A

10


Breaking no-load transformer capacity

kVA

1250

1250

Breaking transfer current

A

_

1700

Expected short-circuit breaking current

kA

_

50

Mechanical life(grade M2)

times

20000

SF6 rated Gas pressure value(at 20 °c)

MPa

0.04~0.05

0.04~0.05




 

 

 

 2 Data for Fuse

 

 

 

 

 

 


 

1 For Load switch


 

 

2 For Combination of electrical 

 

 

 China Circuit Breaker


Related Products

PRODUCT DETAIL Medium voltage withwrawable switchgear

Medium voltage withwrawable switchgear

KYN28A -12 Z
PRODUCT DETAIL outdoor SF6 vaccum circuit breaker

outdoor SF6 vaccum circuit breaker

ZW32-12
PRODUCT DETAIL 11kv 630a outdoor load break switch

11kv 630a outdoor load break switch

FZW28(VSP5)-12
PRODUCT DETAIL Medium Voltage SF6 Ring Main Unit

Medium Voltage SF6 Ring Main Unit

Pannel Unit
PRODUCT DETAIL HV Indoor AC SF6 Load Breaker Switchgear

HV Indoor AC SF6 Load Breaker Switchgear

FLN48-12D
PRODUCT DETAIL RAIN MAIN UNIT --Fully sealed SF6 filled metalswitch panel

RAIN MAIN UNIT --Fully sealed SF6 filled metalswitch panel

XGN15-12
PRODUCT DETAIL Solid Insulated Ring Main Unit

Solid Insulated Ring Main Unit

DH-SRM12

Category: Ring Main Unit

0